Break-glass emergency access
Regain administrative access when the normal sign-in path is unavailable, with strong controls and a complete audit trail.
Plan note: Break-glass emergency access is included on the Essential plan and above (and on Trial); it is not part of the Free plan.
Break-glass is a controlled way to regain administrative access in an emergency. It exists for the rare moment when the normal sign-in path fails, and it is deliberately surrounded by strong controls so that emergency access stays rare, accountable, and safe.
A dedicated standby account handles this: when you cannot sign in at all, because the directory or the usual login is down, a separate, purpose-built account signs in with a hardware security key over its own address.
It is configured under Settings → Advanced → Break-glass emergency access, and stays switched off until you deliberately enable it.
Why it is safe
Emergency access is powerful, so it is built to be trustworthy:
- Hardware security keys. The standby account signs in only with a FIDO2 hardware security key that requires a PIN or biometric. This is phishing-resistant and does not depend on email, SMS, or any external service, so it still works when other systems are down.
- No standing power. The standby account holds no privileges at rest, cannot open any application, and becomes an owner only for the limited duration of an emergency session.
- Time-limited. Every emergency access expires automatically after a set period, and a countdown is shown while it is active.
- Fully recorded. Every step is written to the audit log. Changes to the setup and use of the standby account notify all owners.
Setting it up
Open Settings → Advanced → Break-glass emergency access and turn on the master switch. The standby account appears below it. There is no separate on/off switch: the standby account is armed as soon as one hardware key is enrolled.
There is a single standby account that holds one or more hardware keys. Redundancy comes from enrolling more than one key, each held by a different person and stored in a separate location.
- Enter the key holder's name and select Add key.
- When prompted, insert the hardware security key and complete the verification (touch the key and enter its PIN). Only genuine, attested hardware keys are accepted; a software or synced passkey is refused.
- The key appears in the list. Add a second key, held by another person and stored separately, for redundancy. Remove a key at any time with the delete action next to it; removing the last key deactivates the standby account.
Use the Test key button periodically to confirm a key still works. Testing verifies the key without signing anyone in or changing anything.
Once at least one key is enrolled, select Show emergency card and then Print emergency card to print a card that lists the emergency address, the sign-in steps, and the enrolled key holders. It contains no secret (the key itself is the secret), so store a copy with each hardware key.
Using it in an emergency
- Open the emergency address (from the emergency card).
- Insert the hardware security key, touch it, and enter its PIN.
- You are signed in with owner rights for a limited time and can make the changes needed to restore normal access, then sign out.
Pitfalls and troubleshooting
- Store the keys in separate physical locations. Two keys protect against a single lost or damaged key, but only if one fire, flood, or theft cannot destroy both. Keep them apart (for example, two safes).
- Losing all keys means there is no recovery. There is deliberately no weaker fallback. If every key for the standby account is lost, the emergency path can only be rebuilt by an administrator who can still sign in normally. Plan for this.
- Test regularly. A hardware key that has quietly stopped working is only discovered when you need it most. Use the Test key button on a schedule.
- The standby account cannot open applications. By design it can only reach the admin console to fix settings and directories. It is not a general-purpose account and does not appear in user lists or assignment pickers.
- Changes to the setup alert everyone. Turning the feature off, or removing a key, notifies all owners. This is intended, so that the emergency path cannot be quietly disabled.
- Scope. Break-glass restores access when identity or sign-in is unavailable (for example, a directory outage). It does not address the service itself being unavailable, which is an infrastructure concern.
- Recognising an emergency sign-in. Emergency access produces clearly labelled audit entries and notification emails to owners. Treat an unexpected one as a security event and investigate.
Reference
- Factor requirement. The standby account accepts only attested hardware security keys with user verification.
- Time limits. A standby session expires after a configurable number of minutes and cannot be silently extended.
- Audit events. Emergency access is recorded under dedicated privileged-access event types; see Audit event types.
- Compliance. These controls address emergency-access requirements tracked on the Security health page. The standby account grants a temporary, time-limited increase to owner access rather than a permanent role, so no one holds standing emergency privilege. It is scoped to emergency recovery, not a general privileged-access management vault.